DA668: 24V DC 2A

  • Up to eight 24V DC individually fused outputs
  • Mild steel powder-coated enclosures
  • Input 230V AC @ 50Hz (+/- 10%)

DA669: 24V DC 4A

  • Up to sixteen 24V DC individually fused outputs
  • Mild steel powder-coated enclosures
  • Input 230V AC @ 50Hz (+/- 10%)

DA449:
12V 8A DC or 24V 4A DC

  • Engineer selectable output
  • 8A 12V DC (13.7V) or 24V 4A DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay
  • Input 230V AC @ 50Hz (+/- 10%)

DA448:
12V 5A DC or 24V 2.5A DC

  • Engineer selectable output
  • 5A 12V DC (13.7V) or 24V 2.5A DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay
  • Input 230V AC @ 50Hz (+/- 10%)

DA448-XSM:
12V 5A DC or 24V 2.5A DC

  • Large 405x400x120mm enclosure
  • Engineer selectable output
  • 5A 12V DC (13.7V) or 24V 2.5A DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay

DA447:
12V 3A DC or 24V 1.5A DC

  • Engineer selectable output
  • 3A 12V DC (13.7V) or 24V 1.5A DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay
  • Input 230V AC @ 50Hz (+/- 10%)

DA447-XSM:
12V 3A DC or 24V 1.5A DC

  • Large 405x400x120mm enclosure
  • Engineer selectable output
  • 3A 12V DC (13.7V) or 24V 1.5A DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay

DA446:
12V 1.5A DC or 24V 750mA DC

  • Engineer selectable output
  • 1.5A 12V DC (13.7V) or 24V 750mA DC (27.4V)
  • House and charge VRLA batteries for back-up
  • Mains fail signalling
  • Independent relay
  • Input 230V AC @ 50Hz (+/- 10%)

24V 3A DC DIN Rail Power Centre

  • Continuous & remote controlled outputs
  • Battery back-up support
  • Confirm restart function – allows push to restart for Emergency Stop use.
  • Start from battery power function
  • Mains & low-battery SPCO relay monitoring contacts

24V 5A DC DIN Rail Power Centre

  • Continuous & remote controlled outputs
  • Battery back-up support
  • Confirm restart function – allows push to restart for Emergency Stop use.
  • Start from battery power function
  • Mains & low-battery SPCO relay monitoring contacts

24V 10A DC DIN Rail Power Centre

  • Continuous & remote controlled outputs
  • Battery back-up support
  • Confirm restart function – allows push to restart for Emergency Stop use.
  • Start from battery power function
  • Mains & low-battery SPCO relay monitoring contacts

DA696: 24V DC 2A in-line power supply

  • Single 12V 2A output
  • 1 years warranty
  • Fire retardant ABS enclosure with mounting points
  • Thermally fused

Small basic power supplies, ideal for powering a single device.

DA668-IP66

  • 24V DC 2A
  • IP66 Weather-resistant enclosures
  • Up to eight individually fused outputs
  • 90V to 270V AC @ 47Hz to 63Hz

DA669-IP66

  • 24V DC 4A
  • IP66 Weather-resistant enclosures
  • Up to eight individually fused outputs
  • 90V to 270V AC @ 47Hz to 63Hz

Open-frame 8A 12V DC or 4A 24V DC Power supply with UPS and monitoring

  • Mild steel mounting plate-mounted power supply
  • Selectable 12V or 24V DC output
  • Integrated UPS battery back-up function
  • Mains fail signalling
  • Multi-purpose independent relay
  • Input 230V AC @ 50Hz (+/- 10%)

DA774-P-24VDC

  • Replacement PSU module
  • 24V DC up to 4A output
  • Remote switching outputs
  • Simple layout, easy to install and connect

Plate-mounted 24V DC 2A power supply

  • Up to eight individually fused outputs
  • Replaces DA668-IP66 modules
  • Mild steel mounting plate
  • 90V to 270V AC @ 47Hz to 63Hz

Plate-mounted 24V DC 4A power supply

  • Up to eight individually fused outputs
  • Replaces DA669-IP66 modules
  • Mild steel mounting plate
  • 90V to 270V AC @ 47Hz to 63Hz

Mild steel: Selectable & Dual output

  • Power supplies with selectable or dual-output types
  • Ideal for wall mounting
  • Mounting kit with spares included.

DA748: Dual output rack-mount power supply with VRLA battery support and monitoring

  • 8x 1A 24V DC & 8x 1A 12V DC Output
  • Integrated UPS function VRLA Battery back-up
  • Mains failure signalling
  • Low-battery signalling & automatic disconnect
  • House and charge 2 x 12Ah VRLA batteries

DAV1U:

  • Front-mounted output switches with integrated LEDs
  • Automatic, self-resetting output fuses
  • Slim 1U 19" rack-mount enclosure
  • Designed, manufactured & tested in Britain

DA442:
8A 12V & 4A 24V Regulated DC

  • Available with 12V or 24V DC regulated outputs
  • Easy-to-see output status with front-mounted LEDs
  • 19" 2U rack-mountable enclosure
  • Input voltage range of 96V - 265V AC
  • Removable front plate

DA445:
16A 12V & 8A 24V DC

  • Available with 12V or 24V DC outputs
  • Easy-to-see output status with front-mounted LEDs
  • 19" 2U rack-mountable enclosure
  • Input voltage range of 96V - 265V AC
  • Removable front plate

DA458: 24V DC Rack-mount power supply with VRLA battery support and monitoring

  • Integrated UPS function VRLA Battery back-up
  • Fire enable
  • Mains fail & signalling
  • Low-battery disconnect
  • House and charge 2 x 12Ah VRLA batteries
  • Removable front plate

DA471:
1U Rack mount 8A 24V DC power supply

  • Available with 4, 8 or 16 outputs
  • Mounting kit with spares included.

Power supplies within precision-made mild steel enclosures, finished with a white powder coating for durability.

DA748: Dual output rack-mount power supply with VRLA battery support and monitoring

  • 8x 1A 24V DC & 8x 1A 12V DC Output
  • Integrated UPS function VRLA Battery back-up
  • Mains failure signalling
  • Low-battery signalling & automatic disconnect
  • House and charge 2 x 12Ah VRLA batteries