DA550: Two door normally-closed interlock module
This is a two-door interlock system that monitors the states of both doors. Upon request, the unit will release a door while the request exists, and only if the other door is secure (i.e. door not released and door contacts closed). 12V DC operation.
Ordering information
DA550T: Timed two-door normally-closed interlock module
This is a two-door interlock system that monitors the states of both doors. Upon request, the unit will release a door while the request exists, and only if the other door is secure (i.e. door not released and door contacts closed). 12V DC operation.
Ordering information
Example of an interlock module operation:
DA550: Two door, normally-closed interlock.
The button for door A is pressed. Control for door B is tested. If not released, then monitor for door B is tested. If secure, contacts for door A are operated for time set by your controller.
During this time a signal prevents B from operating. While door A is open the monitor also prevents B from operating. Door B cannot be released until door A release times out and door A is secure.
Ordering information